How sensor interface ASICs turn raw signals into actionable industrial data

Industry 4.0 is built around connected factories that use real-time data to monitor and optimise their operations. Predictive maintenance models, digital twins and Industrial Internet of Things (IIoT) platforms all act on what sensors report, meaning their output is only as reliable as the measurements they receive.

That makes the sensor interface a critical link in the chain. A strain gauge or pressure element produces a signal of just a few millivolts, often in an electrically noisy plant and at the end of a long cable. Turning that raw signal into a trustworthy data point is the job of a sensor interface integrated circuit (IC). In many industrial systems, this is an application-specific integrated circuit (ASIC) designed for a specific sensor and application.

This article explains how the design decisions within early ASIC stages determine whether sensor data is reliable enough to act on in an industrial setting.

What makes industrial sensor data actionable

Actionable data is more than an accurate reading. For a programmable logic controller (PLC) to close a control loop, or for a predictive maintenance model to flag a failing pump, each measurement needs five qualities:

  • Accuracy: The value reflects the physical quantity, with offset, gain and nonlinearity errors corrected.
  • Stability: The value stays accurate across temperature changes and years of service, rather than drifting slowly away from the truth.
  • Consistency: Two sensors of the same type, on two different production lines, report the same value for the same condition.
  • Timeliness: The measurement arrives within the latency the control system or analytics model expects.
  • Validity: The measurement carries information about whether it can be trusted, so the host can tell a genuine process change from a sensor fault.

All five of these qualities are decided, to a large extent, at the sensor interface.

Why raw sensor signals are not ready for industrial control

Industrial sites are often hostile to small signals. As Ross Turnbull, Director of Business Development at Swindon Silicon Systems, puts it:

“Many industrial sensors generate signals with amplitudes of only a few millivolts, leaving very little tolerance for interference. In busy industrial settings, electrical noise from motors, switching power supplies, inverters and high-frequency drives can easily couple into these small signals, distorting them. When sensors are located far from the control cabinet, long cable runs add further vulnerability by picking up common-mode noise or creating ground loops, both of which can shift or obscure the true measurement before it reaches the electronics that process it.”

The sensing element adds its own errors. Offset, sensitivity and temperature behaviour vary from one element to the next, and change as the element ages. Left uncorrected, these errors pass into the control system as plausible but inaccurate numbers, which is the most difficult kind of error for automated decision-making to catch. 

Inside a mixed-signal sensor interface ASIC

A sensor interface ASIC combines analogue and digital circuitry on a single die. Much of mixed-signal ASIC design comes down to partitioning: deciding which functions belong in the analogue domain, which belong in the digital domain, and where the boundary between them should sit. These decisions are made early in the ASIC design flow, and they shape every data-quality attribute above. 

The analogue front end

The front end has one job: to capture the sensor signal faithfully while rejecting everything else. For bridge sensors such as strain gauges and piezoresistive pressure elements, this usually means a differential input stage with a high common-mode rejection ratio (CMRR), so that noise appearing equally on both signal lines is cancelled rather than amplified. The front end can also generate the sensor’s excitation, enabling a ratiometric measurement in which any drift in excitation is cancelled out in the result.

For slow-moving industrial measurands, low-frequency errors matter most. Amplifier offset and flicker (1/f) noise can look exactly like a gradual process change. Chopper stabilisation, which shifts the signal away from the low-frequency region where offset and flicker noise are most significant before amplifying it and shifting it back, is one widely used technique for removing these errors. Protection against electrostatic discharge (ESD) and wiring faults is also integrated, which is important when the sensor connects to the wider plant through a long cable.

Deciding where to digitise

The point of conversion is an architectural choice. Converting early, close to the sensor, protects the measurement from further analogue corruption and allows correction to happen in the digital domain, where it does not drift.

The analogue-to-digital converter (ADC) architecture then follows the measurand. Where pressure, temperature, load and level change slowly and high resolution is required, sigma-delta converters and their inherent noise filtering are often chosen. Vibration monitoring and fast position feedback can need higher sample rates, where a successive approximation register (SAR) converter is often the better fit.

After conversion, a digital core applies per-sensor calibration coefficients stored in non-volatile memory (NVM). For more information about the compensation methods themselves, you can read our sensor interfacing article and the temperature compensation article.

Calibration: consistent data across sensors and sites

A sensor interface ASIC can only correct the errors it has been calibrated to correct. In industrial products, that calibration usually takes place during production test. Each sensor and IC is exercised across a set of pressure, temperature or load points, its individual errors are measured, and the resulting coefficients are written to its memory before it ships.

This step is what makes data consistent across a fleet of sensors. When every unit is characterised against the same references and corrected by the same algorithm, a reading from a sensor in one plant can be compared directly with a reading from a sensor in another. That comparability is a prerequisite for the cross-site analytics that Industry 4.0 platforms rely on.

It is also why test capability matters as much as design capability when choosing an ASIC company. Swindon Silicon Systems combines ASIC design and verification with wafer probe and packaged test, and operates high volume production test facilities, including for precision calibrated system-in-packages.

Diagnostics that support predictive maintenance

Predictive maintenance depends on telling two kinds of change apart. A slow rise in a pressure reading may mean a filter is clogging, which is exactly what the maintenance team needs to know. Or it may mean the sensor itself is degrading, in which case acting on the data sends an engineer to fix a problem that does not exist. Without diagnostics at the sensor, the host has no reliable way to tell the difference.

This is why built-in diagnostics are a significant benefit. Typical functions monitor for open and short circuits on the sensor connections, excitation and supply faults, over-temperature conditions, and readings outside physically plausible limits. Some designs go further, checking bridge balance or running periodic self-tests on the signal path.

In industrial systems, that diagnostic status has to reach the host. On 4–20 mA loops which follow the NAMUR recommendation NE 43, 3.8–20.5 mA is reserved for measurement. The loops use currents at or below 3.6 mA, or at or above 21 mA, to signal a fault. On digital links, diagnostics travel as status information alongside the measurement.

Getting sensor data into IIoT and control systems 

The output stage decides how the processed measurement meets the rest of the plant. Three families are common in industrial sensing:

  • 4–20 mA current loops. Still widespread in process industries, as a current signal is largely unaffected by cable resistance, and the live zero at 4 mA distinguishes a genuine minimum reading from a broken wire.
  • Ratiometric analogue outputs. Referenced to the supply voltage, these suit shorter connections where the host ADC shares the same reference.
  • Digital point-to-point links. IO-Link, standardised by the International Electrotechnical Commission (IEC) as IEC 61131-9, carries the measurement together with parameters, identification and diagnostic data between sensor and automation system.

Above this layer, PLCs, supervisory control and data acquisition (SCADA) systems and IIoT platforms can only work with what the sensor interface delivers. 

Industrial ASIC applications that depend on reliable sensor data

The same architectural principles apply across a wide range of industrial ASIC applications, including:

  • Pressure measurement. Process transmitters, hydraulic systems and pneumatic controls, where bridge sensors need low-noise amplification and precise temperature correction.
  • Position and proximity sensing. Encoders and position sensors in factory automation, where resolution, speed and repeatability determine how accurately machines move.
  • Condition monitoring. Vibration and temperature sensing on motors, pumps and bearings, where diagnostics and sample rate matter as much as absolute accuracy.
  • Load and strain measurement. Weighing, force feedback and structural monitoring, where small bridge signals must be recovered from electrically noisy surroundings.

Reliable data starts at the sensor

Industry 4.0 decisions are made in software, but their quality is set in silicon. A sensor interface ASIC that captures the signal cleanly, digitises it at the right point, is calibrated unit by unit and reports its own health turns raw signals into real-time data that a control system can act on with confidence.

For industrial products, an ASIC can be viable from 1 to 10K units per year and upward. Swindon Silicon Systems is a full turnkey partner, covering design, test and supply under one roof, with experience across industrial, automotive, and aerospace applications. To explore whether a sensor interface ASIC could benefit an industrial application, discover Swindon Silicon Systems’ sensing solutions or get in touch with the team.

A pair of gloved hands holds a circular, transparent petri dish with a grid pattern on its surface, set against a blurred laboratory background.

Explore custom IC solutions for your application

Discuss your project with our expert team. We deliver proven ASIC design, test, and supply with 45+ years of assured delivery.